Schneider Electric TeSys D Green LC2D 3 Pole Reversing Reversing Contactor – 40 A, 24 V dc Coil, 3NO, 18.5 kW

฿24,124.26

SKU: LC2D40ABBE Categories: ,

Description

คุณสมบัติ Value
Coil Voltage 24 V dc
Number of Poles 3
Contact Current Rating 40 A
Power Rating 18.5 kW
Normal State Configuration 3NO
Contact Voltage Rating 690 V ac
Series LC2D
Range TeSys D Green
Number Of Auxiliary Contacts 2
Function Reversing
Auxiliary Contact Configuration 1NO + 1NC
Terminal Type Screw
Width 120mm
Depth 122mm
Maximum Operating Temperature +60°C
Minimum Operating Temperature -25°C
Length 119mm

Schneider Electric LC2D TeSys D Reversing Contactors.

TeSys D reversing Contactors from Schneider Electric combine long mechanical and electrical life to offer a high reliable contactor. The LC2D series is preassembled with reversing power busbar and has been designed for motor control or resistive load applications. The TeSys D contactors offer quick simple setup while maintaining compliance with international standards.

Features and Benefits.

  • Built-in auxiliary contacts for added switching capability
  • Pre-installed interlock
  • Screw connections: IP20 finger-safe terminals with both North American and International terminal markings
  • Can be panel mounted with screws or DIN Rail mounted
  • Easily installed accessories
  • Flexible control circuit to suit a wide range of applications

What does the utilisation category AC1 and AC3 mean for the TeSys contactors?

  • Contactor utilisation categories define the current making and breaking values, based on the type of load to be controlled and the operating cycle conditions.
  • AC-1: This applies to all AC devices with a power factor of at least 0.95. Example of use: resistive load, heating, distribution.
  • AC-3: This applies to squirrel cage motors where breaking occurs while the motor is running.
  • Example of use: all squirrel cage motors, lifts, escalators, conveyors, bucket elevators, compressors, pumps, mixers, air conditioning units.

What is a reversing contactor?

A reversing contactor is an assembly of two of standard contactors, with a mechanical and electrical interlock connecting them. The interlocks allow only one contactor to be closed (giving power supply to the motor) at any time.

Is the TeSys D range a double break pole type contactor?

Yes, the Tesys D range uses linear translation movement that provides double breaking of the poles.

LC2D40ABBE LCD2 TeSys D Green Reversing Contactor.

  • Reversing Contactor.
  • Motor Control, Resistive load applications.
  • AC-1, AC-3 Category.
  • Preassembled with reversing power busbar.
  • Ue Rated voltage <= 690 V AC 25…400 Hz for power circuit.
  • Rated current 40 A (<= 60 °C) at <= 440 V AC AC-3 for power circuit, 60 A (<= 60 °C) at <= 440 V AC AC-1 for power circuit.
  • Circuit Voltage 24 V DC.
  • 1 NO + 1 NC Auxiliary contact.
  • Overvoltage category III.
  • Rated breaking capacity 800 A at 440 V for power circuit conforming to IEC 60947.
  • Complete with a protective cover.
  • Mechanical interlocking.
  • Plate and Rail mounting.
  • Screw clamp terminals, screw connectors.
  • IP20 front face conforming to IEC 60529.

Standards

EN/IEC 60947-4-1, EN/IEC 60947-5-1.