| คุณสมบัติ | Value |
| Coil Voltage | 24 V dc |
| Number of Poles | 3 |
| Contact Current Rating | 6 A |
| Power Rating | 2.2 kW |
| Normal State Configuration | 3NO |
| Contact Voltage Rating | 690 V ac |
| Series | LP1K |
| Range | TeSys K |
| Number Of Auxiliary Contacts | 1 |
| Auxiliary Contact Configuration | 1NO |
| Terminal Type | Screw |
| Width | 45mm |
| Depth | 57mm |
| Length | 58mm |
| Maximum Operating Temperature | +50°C |
| Minimum Operating Temperature | -25°C |
3 Pole Contactors with Screw Clamp or Solder Termination
Contactors have a switching voltage of 440Vac and a coil consumption (ac coils 50 / 60Hz rated) of 4.5VA (Hold in) and 30VA (inrush).
Utilisation category AC3
DIN rail or screw mounting
Ambient air temperature range -25 to +50°C
• Highly reliable
• Excellent quality
• Easily installed accessories
What does the utilisation category AC1 and AC3 mean for the TeSys contactors?
Contactor utilisation categories define the current making and breaking values, based on the type of load to be controlled and the operating cycle conditions.
AC-1: This applies to all AC devices with a power factor of at least 0.95. Example of use: resistive load, heating, distribution.
AC-3: This applies to squirrel cage motors where breaking occurs while the motor is running. Example of use: all squirrel cage motors, lifts, escalators, conveyors, bucket elevators, compressors, pumps, mixers, air conditioning units.
What accessories are available?
• Auxiliary contact blocks with serrated wiping action
• Front mount dust tight auxiliary contact blocks
• Pneumatic time delay blocks
• Transient voltage surge suppressors
• Interface modules and electronic timers
• Mechanical latching blocks
Approvals
CSA, UL, NEMKO, DEMKO, SEMKO, FIMKO
Standards
BS5424 Part 1/IEC 947, VDE 0660, NFC63 110
LP1K0610BD3 TeSys K LP1K Contactor.
- Motor control applications.
- AC-3, AC-4 Category.
- [Ie] rated operational current 6 A at <= 440 V AC AC-3 for power circuit.
- Built-in bidirectional peak limiting diode suppressor
- [Ue] rated operational voltage Power circuit: 690 V AC 50/60 Hz, Signalling circuit: <= 690 V AC 50/60 Hz.
- Control circuit voltage limits Operational: 0.8…1.15 Uc (at <50°C0), Drop-out: 0.1…0.75 Uc (at <50°C).
- 1 NO Auxiliary contact.
- Category III.
- Rated breaking capacity, 110 A at 415 V conforming to IEC 60947, 110 A at 440 V conforming to IEC 60947, 80 A at 500 V conforming to IEC 60947, 110 A at 220…230 V conforming to IEC 60947, 110 A at 380…400 V conforming to IEC 60947, 70 A at 660…690 V conforming to IEC 60947.
- Flame resistant V1 conforming to UL 94, Requirement 2 conforming to NF F 16-101, Requirement 2 conforming to NF F 16-102.
- Safety level B10d = 1369863 cycles contactor with nominal load conforming- to EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load conforming- to EN/ISO 13849-1.
- Rail and Plate mounting.
- Screw clamp terminals.
Approvals
UL, CSA.